bing tracking image

Filter Questions and Answers:

reset filter

Expert Answers about RV Door Parts


  • Steps Open When Door is Closed on Kwikee Series 40 Electric RV Steps
  • It could be that you got the incorrect control board or it was installed incorrectly but my guess is a problem with the door switch. The correct control board just to confirm is the Replacement Control Unit for Kwikee Electric RV Steps part # LC379146. I have attached for you below a list of the door switches. If you can send me a photo of yours, I'd be glad to match this up with a replacement but these aren't specific to the step so there would be no way for us to know what you have exactly....
    view full answer...

  • Will Global Link RV Entry Door Kit Be Easier to Open and Close than Older Latch on RV
  • Yes, going to a new lock/latch for your RV entry door like the part # 295-000019 will be a great solution. Your latch does sound like it's worn out or possibly damaged which is making it hard to use but this replacement will be easy to use and won't require constant lubrication.
    view full answer...

  • Can I Just Use 1 Latch to Secure MORryde StepAbove RV Steps Inside Camper
  • The MORryde StepAbove RV Steps, like part # MR58RR, actually have an adjustment you can make on the latch that I recommend looking at before you start cutting into anything (see attached). If you aren't able to adjust the latch so that you can properly close your screen door I recommend modifying the door as opposed to removing the latch as the steps are designed to use both right and left latches to secure the stairs during travel.
    view full answer...

  • Temp Display Flashes On Everchill RV Refrigerator with French Doors
  • The flashing temperature display on the Everchill RV Refrigerator with French Doors part # WAY44FR indicates the unit is not receiving enough power, the minimum requirement is 11 amps. It's possible the batteries are too far drained which you can check yourself but if they are charged you may have an issue with the trailer's wiring and this would require service by a technician.
    view full answer...

  • Solution for Keeping RV Furrion Refrigerator Doors Closed when Travelling
  • While we don't carry the 10 cubic foot Furrion RV fridge I think I have a great solution for you to keep the doors shut when travelling with the Everchill 12-Volt RV Fridge Door Latch # 324-000149. Once installed this will easily hold the doors shut.
    view full answer...

  • Kwikee Electric RV Steps Won't Stay Extended with Switch Off
  • It sounds like the control module has gone bad on your Kwikee Electric RV Steps as it is not sending the correct signal to the motor to keep the steps open with the switch off. Therefore, you will need to replace this and for that we have the Replacement Control Unit for Kwikee Electric RV Steps part # LC379146 which is a direct replacement.
    view full answer...

  • Magnetic Door Switch Works Opposite Of What It Is Supposed To
  • If you ordered and tested the Replacement Magnetic Door Sensor for Kwikee Electric RV Steps # LC369299 and they work backwards, then you need the Replacement Door Switch for Lippert for Lippert Electric Coach Step # LC301694. Lippert makes two switches that work opposite of each other, one completes the circuit when they are connected, and the other opens when they are connected.
    view full answer...

  • Troubleshooting Kwikee Power Step of RV that Opens When Driving in Rain
  • The water is creating a short for the door switch of the Kwikee 32 Series Electric RV Steps # LC372261 which is basically telling the module that the door is open when it's not. Either there's exposed wire between the door switch circuit which the water is creating a short or the module is allowing water to seep in and create the short there. The step light switch wiring should be purple and black. You might check to see if there's any exposed wiring you could potentially seal up better....
    view full answer...

  • Are Replacement Parts Available For The Bauer Products BP-12ETP Entry Door Lock
  • The only place that you would be able to get any kind of parts for the Bauer Products Motorhome Door Lock # BA64FR would be from Bauer Products directly. Most likely though with the issue you described they'd just tell you to replace the entire door lock.
    view full answer...

  • Troubleshooting A Global Link Entry Door Lock That Won't Open
  • If the lock cylinder of your Global Link RV Baggage Door Slam Latch with Keyed Alike Option # 295-000015 is broken and you can't gain access to your RV the only way to get it open would be to drill out the lock core to loosen handle and then open the door. You can replace the lock core with the following replacements listed below, you'll just need to measure your current lock core to ensure you purchase the correct size. Replacement Cam Lock Cylinder for RVs - Keyed Alike Option - Stainless...
    view full answer...

  • Solution for RV with Kwikee Steps that Are Opening When Ignition is Turned On
  • Most powered RV steps are wired up so that if you turn on the RV the steps will automatically retract. If yours is extending instead that would indicate that this circuit is wired backwards. Do you know what steps you have?
    view full answer...

  • Kwikee Steps 909506000 Extend and Retract with Door While Override Switch Is On
  • The issue you are having your Kwikee Electric Steps could be attributed to a few different issues. The first issue could be that the override switch is not wired properly. I have attached for you below a photo that shows how the steps/switch should be wired. If the wiring is correct then I would be willing to bet the control board is malfunctioning therefore would need to be replaced. The correct replacement control board for you is the Replacement Control Unit for Kwikee Electric RV Steps...
    view full answer...

  • How To Fill Holes In an RV For Screws Which No Longer Fit Inside Enlarged Mounting Holes
  • To fill a hole on an RV will vary depending on how the RV is constructed. Fiberglass sided campers with laminate walls are the most common found on RV's. These walls will have a steel plate mounted inside the wall to provide mounting points for items like a cargo door holder. If you are unable to use a larger diameter mounting screw you will need to fill the holes with Silicone # 0160297 and move the door holder. If you have a camper with aluminum siding it will typically have wood studs...
    view full answer...

  • Troubleshooting Kwikee Steps Working in Reverse Following Magnetic Door Sensor Installation
  • The Replacement Magnetic Door Sensor for Kwikee Electric RV Steps # LC374198 is a "normally closed" switch. Since your steps are working in reverse, it means that you have the wrong sensor and will need to replace it with the "normally open" switch # LC369299.
    view full answer...

  • Replacement Access Door for Fogatie RV Tankless Water Heater
  • Yes, the Replacement Access Door for Fogatti RV Tankless Water Heater # LSB34FR does fit the Fogatti water heater model FS06B1.
    view full answer...

  • Troubleshooting A Malfunctioning Kwikee RV Step Switch
  • I spoke with my contact at Lippert and if you have Kwikee 32 Series steps like the # LC372261 that you linked to then this issue is being caused by the magnet switch you purchased # LC301694. For the 32 Series you would actually need the Replacement Magnetic Door Sensor for Kwikee Electric RV Steps - Rectangle - Black # LC369299. Some switches are wired to be normally open or normally closed so mixing and matching parts can cause communication errors between the components.
    view full answer...

  • Troubleshooting Lippert Kwikee RV Steps that Work Retract Instead of Extend
  • When any of the Lippert Kwikee steps, like part # LC3722862, are working in the opposite fashion that they're supposed to you need to change your door magnets from "normally closed" to "normally open". This should solve your issue. If it doesn't let me know and we'll continue to troubleshoot.
    view full answer...

  • Troubleshooting RV Kwikee Steps that Stopped Working with Ignition Switch
  • Since your Kwikee RV Step isn't working with the ignition switch anymore I'd recommend checking the wiring of the switch and step as there's most likely an issue there. I attached a wiring diagram I took from the install instructions for you to compare to your RV.
    view full answer...

  • Kwikee RV Steps Are Operating In Reverse When The Step Switch Is On
  • It sounds like you have some wires flipped on Kwikee RV steps. I have attached an image I recommend you double check to ensure that your wiring is correct, as that may be the issue. Additionally, it has been reported that the motor orientation could also be causing the opposite affect you're experiencing. What you'll want to do is ensure that the armature on the motor goes through a brush assembly, into the motor case which contains two permanent magnets. If this is turned 180°, this...
    view full answer...

  • Troubleshooting Lippert Powered RV Steps That Extend Then Stop
  • If you have confirmed that the motor in your Lippert or Stromberg Carlson powered RV steps is good and that there are no mechanical issues with the step linkage (that could be causing the step to sometimes stop before extending completely), then the most likely causes for the issue are a bad wiring connection (that allows for intermittent contact), a problem in the control module or a bad door switch. You can try bypassing the door switch to see if that allows the steps to extend fully....
    view full answer...